Pruitt - Inahara Carotid Shunt

 

The gold standard in carotid end arterectomy shunting.

The Pruitt-Inahara Carotid Shunt maintains continuous cerebral blood flow while reducing the risk of trauma or vessel lesions that may occur as a result of clamping.
No-clamp occlusion of internal and common carotid arteries can be achieved with this dual balloon catheter using a small incision, minimal dissection and a short arteriotomy.
Plaque endpoints can be visualized because the balloon holds the artery open during the procedure. This is especially important with high stenoses, when clamps cannot be used.

  • Vessel clamping is not required.
  • Safety balloon with a moveable plastic sheath minimizes risk of internal carotid artery balloon over-inflation (pressure diverted to the safety balloon).
  • Blood flow and pressure monitoring can be performed through the T-port, along with infusion and flushing and removal of embolic particles.
  • Any particles that enter on insertion of the shunt can exit through the side port.

Internal carotid balloon: made of latex, the balloon has an 8 mm diameter at maximum liquid capacity of 0.25 ml.

Common carotid balloon: has a 14 mm diameter at a maximum liquid capacity of 1.50 ml. Blue common carotid balloon corresponds to blue stopcock to simplify common carotid balloon inflation.

Flow rates: the 9F model with a blood pressure of 120/80 mmHg has a flow rate of approximately 180 cc/min with the Pruitt-Inahara outlying shunt and 220 cc/min with the Inahara-Pruitt inlying shunt.

Safety balloon: if the internal carotid balloon over-inflates, the extra pressure is diverted to the safety balloon. 10-12 PSI is ideal for maintaining internal carotid balloon pressure; safety balloon inflates at 13-17 PSI.

Saf-T-Spand Safety Balloon Occlusion Catheter
The Saf-T-Spand is another alternative for surgical procedures that would otherwise require arterial clamping. It is ideal for visualizing high stenosis endpoints in the internal carotid.

  • Safety balloon inflates at 13-17 PSI
  • Soft, clear polyurethane catheter with 5F diameter
  • 7-8 mm balloon diameter at maximum capacity
  • Includes 27 cm catheter, syringe, and stopcock