SX-ELLA Stent Danis

SX-ELLA Stent Danis

Removable stent system for treatment of bleeding esophageal varices
Easy implantation without the need for endoscopy / X-Ray control
Secure hemostasis through direct compression of varices
Oral intake maintained from time of implantation

 

Basic description

Procedure Pack with SX-ELLA Stent Danis

Self-expandable nitinol stent preloaded in a ready-to-use delivery system complete procedure pack including all items required for implantation

Indications

Acute bleeding from esophageal varices

Contraindications

  • Esophageal strictures
  • Recent radiotherapy of the esophagus
  • Tumors of the upper respiratory tract, esophagus or stomach
  • Upper GITbleeding from other causes (e.g. perforation)

Features/Benefits

  • Variable pitches in stent braiding conform to esophageal peristalsis, reducing the risk of stent migration
  • Standardized compression of the varices results in effective hemostasis
  • Atraumatic edges
  • Radiopaque markers at both stent ends and at the mid-point
  • Retrieval loops with gold markers at both stent ends
  • Easy endoscopic stent removal after 7 days

Benefits of the method:

Readily implantable without endoscopy / X-Ray control, also in emergency situations
Patient can continue an oral diet after stent implantation

Additional Description

The procedure pack consists of a plastic carry case containing all items required for stent implantation:
Delivery system pre-loaded with stent, guide wire, plastic syringes, mouthpiece, kidney dish, slobber cloth, waste bag with clip, sterile gloves, instruction for use, patient´s card and self-adhesive product label.

 


dan

dan
dan
dan

Extractor of SX-ELLA Stent Danis

Safe and reliable removal system Unique design Radiopaque markers

 

Basic description

Extractor of SX-ELLA Stent Danis
System for endoscopic stent removal under fluoroscopic control

Indications

Designed solely for extraction of SX-ELLA Stent Danis, a medical device for treatment of bleeding esophageal varices.

Contraindications

Absolute contraindications are unknown.
If a stent remains implanted for more than 7 days, using the extractor is not recommended.

Features/Benefits

  • Safe removal / The whole stent is completely retrieved into the overtube / Prevention of injury and re-bleedig
  • Excellent radiopacity / Stainless steel tube and additional radiopaque marker / Ensures precise fluoroscopic control
  • Unique design / Facilitation of stent removal, even in case of migration into the stomach
  • Simple and reliable system / Possibility of retrieving even stents firmly adherent to the esophageal wall
  • Endoscopic device / Suitable for passage through the working channel of an endoscope

Additional Description

The extractor of SX-ELLA Stent Danis is delivered sterile.
Both overtube sheaths are provided with stainless steel radiopaque markers at the distal end.
150 cm / 2.2 mm extraction bowden cable is available with 7.15 mm (22 F) overtube in a standard active length of 75 cm.

 


dan



dan

dan

dan
 
  כירורגיה
פלסטית
  אורטופדיה
   אנדוסקופיה
 
   ארתרוסקופיה
 
רדיולוגיה 
פולשנית
  אורולוגיה ואורוגניקולוגיה 
  גסטרואנטרולוגיה
  הרדמה וטיפול 
נמרץ
  כירורגיה







































































































כל הזכויות שמורות - א.מ.י טכנולוגיות רפואיות בע"מ
המידע באתר זה הינו כללי ואינפורמטיבי בלבד. לייעוץ רפואי יש לפנות לרופא מומחה.

אודותינו  |  חטיבותמוצרים  | נציגויות  |  אסתטיקה רפואיתיצירת קשר  |  English
msite logo