Basic description
SX-ELLA Stent esophageal (Flexella™)
Self-expandable partialy covered stent preloaded inside the delivery system

Indications:
Dilation of esophageal strictures caused by tumors and/or occlusion of
esophago-respiratory fistula particularly in the upper and middle third of the esophagus.
 

Contraindications:
Strictures in the upper part of esophagus within the distance of 2 cm from
the cricopharyngeal muscle. Impossibility to pre-dilate the stricture to the
minimum diameter of 8 mm.

Technical specification
Stent is made of nitinol wire and has two flared ends. It is covered by
plastic foil (both flared ends are uncovered). Each end of the stent is
provided with the thread with golden marker. Threads allow the stent
repositioning or removal.

Features / Benefits:
High flexibility / Sufficient stent patency even in an extremely curved
position

Excellent expansion force / Good ability to dilate stenosis and resist
increased constriction

Special shape of the stent / Low migration rate

Impermeable and resistant coverage / Prevention of tumor ingrowth,
occlusion of esophago-respiratory fistula, resistant against degradation

Recovery system / Reduction of the frequency of any complication caused
by migrated stent, allowing its removal (impossibility to change the stent position
after 5 days since implantation).

Detachable olive / Safe solution of any lodging of the olive tip within deployed
stent (model 07 only!)

Custom made / Possibility of adaptation according to the request of customer
(e.g. antireflux valve).

Bellow: Both versions of delivery system:

Figure 1 - system “PULL” (model 07) equipped with the olive tip catheter

The dimensions of the delivery system sheath are as follows:
O.D. = 6.6 mm (20F); active length = 75 cm.
Olive tip catheter is provided with simple mechanism allowing
detachment of the olive from the shaft if necessary (model 07 only).
Detached olive passes through GIT by natural way.
The recommended guide wire which is not a part of the set is ultra stiff, 0.035",
length 220 cm.

fle
Figure 2 - system “PUSH” (model 06)
available on request only
 
fle
 
  כירורגיה
פלסטית
  אורטופדיה
   אנדוסקופיה
 
   ארתרוסקופיה
 
רדיולוגיה 
פולשנית
  אורולוגיה ואורוגניקולוגיה 
  גסטרואנטרולוגיה
  הרדמה וטיפול 
נמרץ
  כירורגיה


























































כל הזכויות שמורות - א.מ.י טכנולוגיות רפואיות בע"מ
המידע באתר זה הינו כללי ואינפורמטיבי בלבד. לייעוץ רפואי יש לפנות לרופא מומחה.

אודותינו  |  חטיבותמוצרים  | נציגויות  |  אסתטיקה רפואיתיצירת קשר  |  English
msite logo